Essais comparatifs SFX SFX Essai comparatif St. Gobain - SGIB, Verre
Organisateur de l'essai interlaboratoires:
Saint Gobain Isover - CRIR
Matériel d'essai de l'anneau:
SGIB, verre borosilicate
Étude terminée:
2002 - 6
Littérature:
Rapport final
Éléments principaux [%]
CRB | RV | 1sRV | Z-Score | |
Na₂O | 15,780 | 15,810 | 0,130 | --- |
MgO | 3,080 | 3,200 | 0,100 | --- |
Al₂O₃ | 1,610 | 1,600 | 0,070 | --- |
SiO₂ | 65,440 | 65,780 | 0,320 | --- |
P₂O5 | 0,030 | 0,030 | 0,007 | --- |
SO₃ | 0,090 | 0,080 | 0,030 | --- |
K₂O | 0,600 | 0,610 | 0,030 | --- |
CaO | 7,660 | 7,600 | 0,150 | --- |
TiO₂ | 0,028 | 0,030 | 0,007 | --- |
Fe₂O₃ tot. | 0,210 | 0,240 | 0,020 | --- |
MnO | 0,407 | 0,410 | 0,023 | --- |
Les oligo-éléments [µg/g]
CRB | RV | 1sRV | Z-Score | |
Ba | 200,00 | --- | --- | --- |
Cr | 90,00 | --- | --- | --- |
Rb | 10,00 | --- | --- | --- |
Sr | 10,00 | --- | --- | --- |
Zr | 320,00 | --- | --- | --- |
légende
CRB
Les résultats CRB
essai interlaboratoires
Résultats collaborative study
1s-RV
Écart-type étude collaborative
Z-Score
Différence entre la valeur mesurée et l'étude moyenne
*
Valeur non certifié